`Case 1:17-cv-00770-JDW Document 250-91 Filed 10/25/23 Page 1 of 4 PagelD #: 29032
`
`EXHIBIT 88
`EXHIBIT 88
`
`
`
`Case 1:17-cv-00770-JDW Document 250-91 Filed 10/25/23 Page 2 of 4 PageID #: 29033
`
`
`WIRTGEN AMERICA, INC.,
`
`
`IN THE UNITED STATES DISTRICT COURT
`FOR THE DISTRICT OF DELAWARE
`
`)
`
`)
`
`Plaintiff/Counterclaim-Defendant, )
`
`)
`
`)
`
`)
`
`)
`
`)
`Defendant/Counterclaim-Plaintiff. )
`
`C.A. No. 1:17-cv-00770-JDW
`
`
`
`
`
`v.
`
`
`CATERPILLAR INC.,
`
`
`
`
`
`
`
`
`
`
`
`REPLY EXPERT REPORT OF DR. CHRISTOPHER RAHN
`
`
`
`
`
`1
`
`HIGHLY CONFIDENTIAL – OUTSIDE ATTORNEYS’ EYES ONLY
`
`
`
`Case 1:17-cv-00770-JDW Document 250-91 Filed 10/25/23 Page 3 of 4 PageID #: 29034
`
`
`which is in fact consistent with mine. See Smith Rebuttal Report, ¶¶ 81–82, 134–
`
`136. As I explained above, Dr. Smith erroneously suggests that the asserted claims
`
`require that the values displayed on the Caterpillar’s grade and slope user interface
`
`(which constitutes a recited indication and setting device) are the exact same
`
`values (e.g., in magnitude and units) that are used for controlling the machine.
`
`49. Moreover, Dr. Smith suggests that Dr. Valerdi’s opinion was that the
`
`value displayed on the user interface of the Accused Sensor Swapping Machines
`
`was not used to control grade and slope. That is not the case. The value displayed
`
`on the user interface is the currently measured actual value. The controller,
`
`however, is only required to be conditioned on set values and sensed current actual
`
`values of the operating parameters. Thus, the controller uses conditioned (e.g.,
`
`filtered, amplified/scaled, or offset) versions of the currently measured actual
`
`values. Thus, the currently measured actual values are conditioned to go from the
`
`displayed value to what the controller uses. Indeed, Caterpillar’s own documents
`
`confirm that the Caterpillar’s grade and slope system both (1) uses the currently
`
`measured actual value to control the machine and (2) displays the currently
`
`measured actual value on the user interface:
`
`The system compares the measured position against a preset value. The
`system feeds the measured values back to the operator through the
`display. The system can also automatically drive the hydraulics to
`maintain the preset values.
`CAT-770_040200 (Grade & Slope Manual) at 0212 (emphasis added).
`
`34
`
`HIGHLY CONFIDENTIAL – OUTSIDE ATTORNEYS’ EYES ONLY
`
`
`
`Case 1:17-cv-00770-JDW Document 250-91 Filed 10/25/23 Page 4 of 4 PageID #: 29035
`
`X.
`
`Conclusion
`This report contains my complete opinions as of today based on discovery
`
`provided by Defendant. I reserve the right to amend, modify, or supplement this
`
`report in the even additional discovery is provided by Defendant, including any
`
`expert opinions offered by Defendant.
`
`Executed on July 7, 2023
`
`Christopher Rahn, Ph.D.
`
`
`
`HIGHLY CONFIDENTIAL – OUTSIDE ATTORNEYS’ EYES ONLY
`
`