`FEDERAL ENERGY REGULATORY COMMISSION
`Office of Energy Projects
`Division of Dam Safety and Inspections – New York Regional Office
`19 West 34th Street, Suite 400
`New York, NY 10001
`
`Telephone No. (212) 273-5900 Fax No. (212) 631-8124
`
`
`In reply refer to:
`
`Androscoggin River and Kennebec
`River Watershed Projects
`
`November 22, 2021
`
`
`Ms. Kelly Maloney
`Manager, Licensing & Compliance
`Brookfield Renewal Energy Group
`150 Main Street
`Lewiston, Maine 04240
`
`Subject: 2021 Dam Safety Inspections Conference Call Follow-up for the
`
` Androscoggin River and Kennebec River Watershed Projects.
`
`Dear Ms. Maloney:
`
`
`This letter is a follow up to the conference call on November 15, 2021 with our
`Project Engineer, Harold Kamara, regarding the Owner’s Dam Safety Inspections performed
`by Brookfield. Due to Covid-19 travel restrictions, we were unable to perform the 2021 dam
`safety inspection of the listed projects. As per FERC’s request, Brookfield performed dam
`safety inspections on various dates during 2021 and submitted the completed Owner’s
`Inspection Forms (OIF) on October 19, 2021 (see table below).
`
`
`Project Name
`
`Project & NATDAM #s
`
`Androscoggin River Watershed Projects
`Aziscohos
`4026-ME, ME00024 &
`ME00424
`Kennebec River Watershed Projects
`Harris Project
`2142-ME, ME00090,
`(Indian Pond)
`ME83060, ME83061
`Wyman Project
`2329-ME, ME00089
`
`Date
`Inspected
`
`Inspected By
`
`OIF Date
`Submitted
`
`7/19/2021 Chris Karam &
`Nick Weaver
`
`10/19/2021
`
`10/6/2021 Stephen Hofacker
`& Dave Rancourt
`5/12/2021 Stephen
`Hofacker, Lon
`Miller & Colin
`Bates
`
`10/19/2021
`
`10/19/2021
`
`
`
`Project No. 309-PA
`
`
`Hydro Kennebec
`Project
`Weston Project
`
`Flagstaff Project
`
`2611-ME, ME00083,
`ME83054
`2325-ME, ME00085 &
`ME83033
`2612-ME, ME00127
`
`2
`5/25/2021 Stephen Hofacker
`& Dave Hay
`Stephen Hofacker 10/19/2021
`
`10/19/2021
`
`8/8/2021
`
`9/24/2021 Chris Karam &
`Dave Greeley
`
`10/19/2021
`
`
`
`Based on our review of the OIFs and discussion during the conference call, you noted
`that the projects are safe for continued operation, and there were no immediate dam safety
`issues identified during the inspections that required immediate remedial action. In addition,
`there was no unusual instrument readings or trends that would indicate a potential or existing
`dam safety concern.
`
`
`We appreciate your effort in performing the Dam Safety Inspections. Your continued
`interest in dam safety is appreciated. If you have any questions, please contact Mr. Harold
`Kamara at (212) 273-5916 or email at harold.kamara@ferc.gov.
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`Sincerely,
`
`John Spain, P.E.
`Regional Engineer
`
`