`Page 196 o f 706
`
`In the simulcast system, the transceiver will synchronize the time with the call control server via this port. This port is used for voice and data interaction
`between the transceiver and the call control server, and it must be unique from other ports.
`
`Range
`
`10 2 4-65535
`
`Step
`
`efault
`
`1 D
`
`9702
`
`Note
`
`This feature is available for simulcast transceiver only.
`
`Edit - Conventional - General Setting - Network - Simulcast Param eter - Synchronize Service RTP Port
`
`Synchronize Service RTP Port H
`
`In the simulcast system, the call control server will receive the synchronized time from the transceiver via this port, which is used for voice and data
`interaction between the call control server and the transceiver.
`
`Range
`
`10 2 4 -6 5 5 3 5
`
`Step
`
`efault
`
`1 D
`
`9702
`
`Note
`
`This feature is available for simulcast transceiver only.
`
`Edit - Conventional/XPT Trunking - General Setting - Network - IP Connect Setting
`
`IP Connect Setting
`
`This feature allows multiple repeaters in different places to communicate via the IP Connect.
`
`• Repeater Type
`• Jitter Buffer Lengtli
`• Network Authentication Kev
`• M aster IP
`• M aster UDP Port
`• IP Connect Networking UDP Port
`• P2P Firewall Open Timer
`• Voice & Data Service
`• Voice & Data UDP Port
`• RDAC Service
`• RDAC UDP Port
`• M aster Domain Name O n/Off
`• domain names
`
`Edit - Conventional/XPT Trunking - General Setting - Network - IP Connect Configuration - Repeater Type
`
`Repeater T y p e©
`
`CX-1295.0196
`
`Mote-1053-05745655
`
`MOTOROLA EX. 2010
`IPR2017-02183
`Page 196 of 706
`
`
`
`Edit
`
`Page 197 o f 706
`
`This parameter allows the user to configure the operation mode o f the repeater:
`
`Option Description
`
`• Single Site: The repeater works in Local mode and does not support any functionality o f the IP Connect, (only available for Conventional repeaters)
`• Mater: The repeater serves as the master o f the IP site and manages other repeaters in the same site.
`Only one master is allowed in one site.
`• Slave: The repeater serves as the slave and connects to the master to build up the IP site.
`Multiple slave repeaters are allowed in one site.
`• SubMaster: The sub master repeater is used to connect multiple IP sub site, and has the same features as that o f m aster repeater and slave repeater.
`When it works as the master o f a sub site, it can manage other repeater in this sub site; When works as a slave repeater o f a higher sub site, it can
`connect to the m aster repeater o f this higher sub site, and build up the sub site with other repeaters.
`
`Default
`
`• Conventional repeaters: Single Site
`• XPT repeaters: M aster
`
`Edit - Coiiventioiial/XPT Trunking - General Setting - Network - IP Connect Setting - Jitter Buffer Length
`
`Jitter Buffer L en gth ©
`
`This parameter defines the length o f buffer area for the repeater to process the received voice and data in the IP network. W hen the network comiectivity is
`poor, the buffer length can be increased to improve the communication continuity.
`
`Range
`
`1 -C 8
`
`Step
`
`efault
`
`ote
`
`1 D
`
`1 N
`
`This feature is available for Digital mode only.
`
`This feature is disabled w hen Repeater Type is set to Single Site.
`
`Edit - Conventional/XPT Trunking - General Setting - Network - IP Connect Setting - Network Authentication Key
`
`Network Authentication K e y ©
`
`This feature allows the user to specify the authentication key used for accessing IP network. All slave repeaters within the same IP site must share the same
`key as the master repeater.
`
`And
`To ensure the user’s privacy, after the data o f the radio which uses the authentication key is read, the authentication password will be disguised by
`the password will not be written during the writing and cloning o f the encrypted text. W hen the authentication key is plain text, it will be written into the
`radio during the data writing.
`
`Range
`
`Maximum: 40 characters. Valid characters include 0-9 and A-F. If this option is left blank, it means the authentication key is not enabled.
`
`Default
`
`0000000000000000000000000000000000000000
`
`Note
`
`• This feature is available for Digital mode only.
`• This option is not available if Repeater Type is set to Single Site.
`
`Edit - Conventional/XPT Trunking - General Setting - Network - IP Connect Configuration - M aster IP
`
`CX-1295.0197
`
`Mote-1053-05745656
`
`MOTOROLA EX. 2010
`IPR2017-02183
`Page 197 of 706
`
`
`
`Edit
`
`M a ste r I P ©
`
`Page 198 o f 706
`
`This parameter is used to specify the IP Address o f the master in the IP network.
`
`Range
`
`l.O.O.O -C 126.255.255.255, 128.0.0.0 "C 223.255.255.255
`
`Default
`
`o.o.o.o
`
`Note
`
`• Tliis feature is available for Digital mode only.
`• This feature is disabled when Repeater type is set to Master or Single Site.
`
`• When Repeater Type is set to Slave, if M aster Domain Name O n/O ff is selected, then M aster IP will be read-only.
`
`Edit - Conveiitional/XPT Trunking - Gtnera] Setting - Network - IP Connect Setting - Master UDP Port
`
`M a ste r U D P P o r t ® ©
`
`This feature allows the user to specify the User Datagram Protocol (UDP) port number o f the master within the IP network. UDP is a protocol used for peer-
`to-peer services within the IP network.
`
`Range
`
`1024 -C 65535
`
`Step
`
`efault
`
`1 D
`
`50000
`
`Note
`
`• Tliis feature is available for Repeater in Digital mode only.
`• This feature is disabled when Repeater Type is set to IP Site M aster or Single Site.
`
`Edit - Conventional/XPT Trunlving - General Setting - Network - IP Connect Setting - IP Connect Networking UDP Port
`
`IP Connect Networking UDP P o r t©
`
`This port is used to establish and maintain the network comiection between repeaters connected to each other via IP address.
`
`This port m ust be different from IP Multi-site Service UDP Port. Remote RDAC UDP Port. Super M aster Multi-site UDP Port. Super M aster RDAC UDP
`Port, Super M aster Multi-site Networking UDP Port.
`
`Range
`
`1 0 2 4-65535
`
`Step
`
`efault
`
`1 D
`
`50000
`
`Note
`
`CX-1295.0198
`
`Moto-1053-05745657
`
`MOTOROLA EX. 2010
`IPR2017-02183
`Page 198 of 706
`
`
`
`Edit
`
`Page 199 o f 706
`
`This feature is available for Digital mode only.
`
`This feature is disabled when Repeater Type is set to Single Site.
`
`Edit - Conventional/XPT Trunking - General Setting - Network - IP Connect Setting - P2P Firewall Open Timer
`
`P2P Firewall Open T im er©
`
`Repeaters in the IP network will send a message to each other at a regular interval to keep their connection alive. This feature allows the user to specify the
`interval.
`
`Range
`
`5 "C 30 seconds
`
`Step
`
`1 second
`
`Default
`
`6 seconds
`
`Note
`
`This feature is available for Digital mode only.
`
`This feature is disabled when Repeater Type is set to Single Site.
`
`Edit - Conventional - General Setting - Network - IP Connect Setting - Voice & Data Service
`
`Voice & Data S erv ice 'H ©
`
`This option allows the user to activate DM R services in M ulti-site Connect mode.
`
`Option Description
`
`• Checked: To allow.
`• Unchecked: Not to allow.
`
`Default
`
`Unchecked
`
`Note
`
`This option is available in digital mode o f repeaters only.
`
`This option is unavailable when the Repeater Type is set to Single Site
`
`Edit - Conventional/XPT Trunking - General Setting - Network - IP Connect Setting - Voice & Data TJDP Port
`
`Voice & Data UDP P o r t ^ ©
`
`This option allows the user to configure the port used for voice and data services, including transm itting and receiving DM R data or voice over the network.
`Note that the port m ust be different from M aster UDP Port and RDAC UDP Port.
`
`Range
`
`10 2 4 -6 5 5 3 5
`
`Step
`
`efault
`
`1 D
`
`CX-1295.0199
`
`Moto-1053-05745658
`
`MOTOROLA EX. 2010
`IPR2017-02183
`Page 199 of 706
`
`
`
`Edit
`
`50001
`
`Note
`
`Page 200 o f 706
`
`This option is available in digital mode o f repeaters only.
`
`This option is unavailable when the Repeater Type is set to Single Site.
`
`Edit - Conveiitional/XPT Trunking - General Setting - Network - IP Connect Configuration - Service C ontrol Port
`
`Service Control P o r tH ©
`
`This parameter is used to specify Service Control Port o f the master in a IP network. Tlie XPT repeaters broadcast status message through this port, and
`coinmunicate with other XPT repeaters.
`
`Range
`
`1024j«65535
`
`Step
`
`efault
`
`1 D
`
`50003
`
`Note
`
`• This feature is available for Digital mode only.
`• This feature is disabled when Repeater Type is set to Single Site.
`• The Service Control Port o f all XPT repeaters in a XPT site must be the same.
`
`Edit - Conventional/XPT Trunking - General Setting - Network - IP Connect Setting - RDAC Service
`
`RDAC S erv ice H l©
`
`This option allows the user to enable RDAC (Repeater Diagnostic and Control) Service .
`
`Option Description
`
`• Checked: To allow.
`• Unchecked: N ot to allow.
`
`Default
`
`Unchecked
`
`Note
`
`This option is available in digital mode o f repeaters only.
`
`This option is unavailable when the Repeater Type is set to Single Site.
`
`Edit - Conventional/XPT Trunking - General Setting - Network - IP Connect Setting - RDAC UDP Port
`
`RDAC U D P P o rtH ©
`
`This option allows the user to configure the UDP port used for RDAC service. Note that this port m ust be different from M aster UDP Port and Voice &
`Data UDP Port.
`
`Range
`
`1024 -C 65535
`
`Step
`
`CX-1295.0200
`
`Mote-1053-05745659
`
`MOTOROLA EX. 2010
`IPR2017-02183
`Page 200 of 706
`
`
`
`Page 201 o f 706
`
`Edit
`
`efault
`
`1 D
`
`50002
`
`Note
`
`This option is available in digital mode o f repeaters only.
`
`This option is unavailable when the Repeater Type is set to Single Site.
`
`Edit - Conventional - General Setting - Network - IP Connect Configuration - Master Domain Nam e On/Off
`
`Master Domain Name O n / O f f H
`
`This parameter decides whether to enable the DNS feature of the slave in IP Multi-site Connect services.
`
`Through the DNS server, the slave can obtain the IP address o f the master through the master's domain names. Thus, dynamic IP address
`is allowed for the master, which is effective in lowering IP Multi-site Connect costs.
`
`Option Description
`
`• Checked: To enable the DNS feature of the slave.
`• Unchecked: To disable the DNS feature of the slave.
`
`Default
`
`Unchecked
`
`Note
`
`• Before using this feature, please ensure the domain name for the repeater has been obtained from the DNS providers supported by the router and the
`router has the DDNS function.
`• Tliis feature will be available for repeater, except simulcast transceiver.
`
`• This feature is valid when the repeater is in Digital mode (i.e.: it is on digital channel and/or in Digital mode of the mixed channel) and Repeater
`Type is set to Slave.
`• When Repeater Type is set to Slave, if M aster Domain Name O n/O ff is selected, then M aster IP will be read-only.
`
`Edit - Conventional - General Setting - Network - IP Connect Configuration - domain names
`
`domain names H
`
`This parameter allows the user to set the domain name o f the Master.
`
`A domain name is corresponding to an IP address o f the master. Thus, through the DNS server, the slave in the IP Multi-site Network can
`resolve this domain name to the corresponding IP address o f the master, even though this IP address may change.
`
`Range
`
`0 - 253 characters
`
`Note
`
`• This feature will be available for repeater, except simulcast transceiver.
`• This parameter will be read-only when M aster Domain Name O n/O ff is unchecked.
`
`Edit - Conventional/XPT Trunking - General Setting - Network - SubMaster/Slave Parameters
`
`SubMaster/Slave P a r a m e t e r s H ©
`
`SubMaster is a feature enabling a repeater to work as a routing device for connecting multiple IP M ulti-site Connect systems, so as to extend the
`communication coverage. In this way, cross-network services such as RDAC can be achieved. You can designate any repeater as the SubMaster.
`
`SubMaster slave parameters are the parameters need to be set when the submaster works as a slave repeater o f a higher sub site. These parameters need to
`be configured: M aster IP. M aster UDP Port. Voice & Data UDP Port. Voice & Data Service. Voice «& Data UDP Port. RDAC Service and RDAC UDP
`
`CX-1295.0201
`
`Moto-1053-05745660
`
`MOTOROLA EX. 2010
`IPR2017-02183
`Page 201 of 706
`
`
`
`Edit
`
`Port.
`
`Page 202 o f 706
`
`The following illustration shows how the communication between two IP M ulti-site networks is reahzed. This is the same case with the communication
`among multiple networks. To realize the communication between sub site 1 and sub site 2, master repeater A or master repeater B m ust set to be a sub
`master, and the other one still works as a m aster repeater. Configuration for slave repeaters rem ain the same.
`
`IP Mulli-site Cnnnect Network 2
`
`IP Multi-Site C o nnect N elw orlt 1
`
`• M aster IP
`• M aster UDP Port
`• IP Connect Networking UDP Port
`• Voice & Data Service
`• Voice & Data UDP Port
`• RDAC Service
`. RDAC UDP Port
`
`O ption D escription
`
`• Checked: To enable a repeater to be a SubMaster for mutual communication.
`• Unchecked: N ot to enable a repeater to be a SubMaster.
`
`D efault
`
`Unchecked
`
`Note
`
`• This feature is available in digital mode of repeaters only.
`• You can configure the SubM aster/Slave Parameters for the repeater only when Repeater Type is set to SubMaster.
`• When Repeater Type is set to SubMaster, if both M aster Domain Name O n/O ff is selected, then M aster IP will be read-only.
`
`Edit - Conventioiial/XPT Trunkiiig - Gtiieral Setting - Network - SubMaster/Slave Parameters - Master IP
`
`Master j p H ©
`
`This parameter is used to configure the Ethernet IP for the m aster which the Sub M aster connect with.
`
`For more information about Sub Master, see Repeater Type.
`
`Range
`
`l.O.O.O - 126.255.255.255, 128.0.0.0 - 223.255.255.255
`
`Default
`
`o.o.o.o
`
`Note
`
`• Tliis feature is available in digital mode of repeaters only.
`• When Repeater Type is set to Master, if both Super M aster Sei-yice and M aster Dom ain Name O n/O ff are selected, then M aster IP will be read
`only.
`
`Edit - Conventional/XPT Trunking - General Setting - Network - SubMaster/Slave Parameters - Master UDP Port
`
`M aster UDP P o r t H ©
`
`CX-1295.0202
`
`Moto-1053-05745661
`
`MOTOROLA EX. 2010
`IPR2017-02183
`Page 202 of 706
`
`
`
`Edit
`
`Page 203 o f 706
`
`This option allows users to configure the M aster UDP Port o f the master which the sub m aster connect with. This port is used to provide voice and data
`service. Note that this port number must be unique.
`
`For more information about SubMaster, see Repeater Type.
`
`Range
`
`10 2 4-65535
`
`Default
`
`50000
`
`Edit - Conventional/XPT Truiikiiig - Gtiieral Setting - Network - SubMaster/Slave Parameters - IP Connect Networking TIDP Port
`
`IP Connect Networking UDP P o r tH ©
`
`This port is used to establish and maintain the network comiection between the repeaters and the SubMaster.
`
`For more information about Super Master, see Repeater Tvne.
`
`This port shall be set differently from IP Connect Networking UDP Port. Voice & Data UDP Port. RDAC UDP Port. Voice & Data UDP Port. RDAC UDP
`Port.
`
`Range
`
`1024-65535
`
`Step
`
`efault
`
`1 D
`
`60000
`
`Note
`
`This feature is available for repeaters in digital mode only.
`
`Edit - Conventional - General Setting - Network - SubMaster/Slave Parameters - Voice & Data Service
`
`V o ic e & D a ta S e r v i c e ^ ©
`
`W hen the service is enabled, the repeater can transm it DM R data or voice over the IP Multi-site Connect network, extending the repeater's coverage greatly.
`
`For more information about SubMaster, see Repeater Type.
`
`Option Description
`
`• Checked: to enable the service.
`• Unchecked: not to enable the service.
`
`Default
`
`Unchecked
`
`Note
`
`This feature is available in digital mode o f repeaters only.
`
`This option is available only when R epeater Type is set to SubMaster.
`
`Edit - Conventional - General Setting - Network - SubMaster/Slave Parameters - Voice & Data UDP Port
`
`Voice & Data UDP P o r tH ©
`
`CX-1295.0203
`
`Mote-1053-05745662
`
`MOTOROLA EX. 2010
`IPR2017-02183
`Page 203 of 706
`
`
`
`Edit
`
`Page 204 o f 706
`
`This option allows users to configure the IP Connect Networking UDP Port o f the repeater which works as the sub master. This port is used by the sub
`master to provide IP M ulti-site service. Note that this port number must be unique.
`
`For more information about SubMaster, see Repeater Type.
`
`Range
`
`10 2 4-65535
`
`Step
`
`efault
`
`1 D
`
`60001
`
`Edit - ConYeiitional/XPT Trunking - General Setting - Network - SubMaster/Slave Parameters - RDAC Service
`
`RDAC S erv ice H l©
`
`W hen this service is enabled, users can use the RDAC software to diagnose and control all the master and slave repeaters which the repeater (sub master)
`connects with.
`
`For more information about Sub Master, see Repeater Type.
`
`Option Description
`
`• Checked: to enable the service
`• Unchecked: not to enable the service
`
`Default
`
`Unchecked
`
`Note
`
`This option is available only when Repeater Type is set to SubMaster.
`
`Edit - Conventional/XPT Trunlting - General Setting - Network - SubMaster/Slave Parameters - RDAC UDP Port
`
`RDAC UDP Port*® ©
`
`To set the RDAC UDP Port that the sub master uses for RDAC service. Note that this port number m ust be unique.
`
`For more information about Super Master, see Repeater Type.
`
`Range
`
`10 2 4-65535
`
`Step
`
`efault
`
`1 D
`
`60002
`
`Edit - Conventional/XPT Trunking - General Setting - Network - Application Programming Interface
`
`Application Programming Interface
`
`In the IP network, the third-party equipment can be connected to the repeater through a specific port, so as to realize the tliird party services.
`
`CX-1295.0204
`
`Moto-1053-05745663
`
`MOTOROLA EX. 2010
`IPR2017-02183
`Page 204 of 706
`
`
`
`Edit
`
`Page 205 o f 706
`
`You can set the following parameters for the connection o f the repeater and the third party equipment.
`
`• Foi-ward to PC
`• Tliird Party Connect Mode
`• RTP Packet Buffer Length
`• Tliird Party Server IP
`• /YPI interface Mode
`• Radio RRS S lotl Port
`• Radio RRS Slot2 Port
`• Radio GPS Slotl Port
`• Radio GPS Slot2 Port
`• Radio Telemetry Slotl Port
`• Radio Telemetry Slot2 Port
`• Radio TMS S lotl Port
`• Radio TMS Slot2 Port
`• Radio Call Control Slotl Port
`• Radio Call Control Slot2 Port
`• Radio Voice Service Slotl Port
`• Radio Voice Service Slot2 Port
`• A ialog Call Control Port
`• Analog Voice Service Port
`• Self-Defined Message Slotl Port
`• Self-Defined Message Slot2 Port
`• RRS Port Identifier
`• GPS Port Identifier
`• Telemetry Port Identifier
`• SeU-Defined Message Port Identifier
`• RCP Port Identifier
`
`Edit - Conventional/XPT Trunking - General Setting - Networli - Application Programming Interface - Forward to PC
`
`Forward to P c H ©
`
`The repeater can be a bridge to realize the communication between the terminals and PC-end applications such as Dispatcher Application.
`
`Option Description
`
`• Checked: to enable this function.
`• Unchecked: not to enable this function.
`
`Default
`
`Unchecked
`
`Note
`
`This feature is available on the digital channel only.
`
`Edit - Conventional/XPT Trunlting - General Setting - Networl^ - Application Programming Interface - Third Party Connect Mode
`
`Third Party Connect Mode
`
`This is used to set the mode o f the connection between the third party equipment and the repeater.
`
`Option Description
`
`• Normal: The third party equipment connects to only one o f the repeaters in the IP multi-site network, and sends all the control data and commands to
`the connected repeater, which will transfer all the infoimation to other repeaters over the network.
`• Selective: The third party equipment connects to each o f the repeaters in the IP multi-site network, and send all the control data and commands to
`each repeater.
`
`Default
`
`Normal
`
`Note
`
`This feature is available on repeaters only.
`
`E dit - Conventional/X PT T runking - G eneral Setting - N etw ork - A pplication Program m ing Interface - R T P Packet B uffer Length
`
`CX-1295.0205
`
`Moto-1053-05745664
`
`MOTOROLA EX. 2010
`IPR2017-02183
`Page 205 of 706
`
`
`
`Edit
`
`Page 206 o f 706
`
`RTP Packet Buffer L e n g th Q
`
`This parameter decides the buffer size o f the repeater in IP M uhi-site Connect mode for audio packet buffering. The audio packet is RTF-based, and is
`received by the repeater from the network. When in network congestion, the user can increase the buffer size for better capability of the repeater to buffer
`RTP audio packets.
`
`Range
`
`1 - 8
`
`Step
`
`efault
`
`ote
`
`1 D
`
`1 N
`
`This feature is only available for repeater, except portable repeater and simulcast transceiver.
`
`Edit - Coiiventioiial/XPT Trunking - General Setting - Networit - Application Programming Interface -Third Party Server IP
`
`Third Party Server IP
`
`This is used to set the IP address o f the third party equipment which connects to the repeater.
`
`Range
`
`l.O.O.O "C 126.255.255.255, 128.0.0.0 ~C 223.255.255.255
`
`Default
`
`o.o.o.o
`
`Note
`
`This feature is available on repeaters only.
`
`Edit - Conventional/XPT Trunking/XPT Trunking - General Setting - Network - Application Programming Interface - API interface Mode
`
`API interface Mode
`
`Sets the API interface mode which the repeater provides for the third party.
`
`Option Description
`
`• Hytera Defined Mode: Hytera defined standard API interface. W hen receiving an encrypted data which needs to be transferred to a third party, the
`repeater will decode it before transfem ng.
`• End to End Encryption Mode: Hytera defined End to End Encryption API interface. W hen receiving an encrypted data which needs to be transferred
`to a third party, the repeater will transfer it to the third party directly without decoding.
`This mode is compatible with Hytera Defined Mode.
`
`Default
`
`Hytera Defined Mode
`
`Edit - Conventional/XPT Trunking - General Setting - Netw ork - Application Programming Interface - Radio RRS Slotl Port
`
`Radio RRS Slotl P o r t ® ©
`
`To set the port number that the repeater uses for retransmitting radio registration service. This number m ust be unique.
`
`CX-1295.0206
`
`Moto-1053-05745665
`
`MOTOROLA EX. 2010
`IPR2017-02183
`Page 206 of 706
`
`
`
`Page 207 o f 706
`
`Edit
`
`Range
`
`10 2 4-65535
`
`Step
`
`efault
`
`1 D
`
`30001
`
`Note
`
`In an IP Multi-site Connect network, when a third party needs to use this function, it m ust share the same port num ber as the repeater.
`
`Edit - Conventioiial/XPT Trunkiiig - General Setting - Net^vork - Application Programming Interface -Radio RRS SIot2 Port
`
`Radio RRS Slot2 P o r t H ©
`
`To set the port number that the repeater uses for retransmitting radio registration service. This number m ust be unique.
`
`Range
`
`10 2 4-65535
`
`Step
`
`efault
`
`1 D
`
`30002
`
`Note
`
`In an IP Multi-site Connect network, when a third party needs to use this function, it must share the same port num ber as the repeater.
`
`Edit - Conventional/XPT Trunking - General Setting - Network - Application Programming Interface - Radio GPS Slotl Port
`
`Radio GPS Slotl Port H ©
`
`To set the port number that the repeater uses for retransmitting GPS service. This number m ust be unique.
`
`Range
`
`10 2 4-65535
`
`Step
`
`efault
`
`1 D
`
`30003
`
`Note
`
`In an IP Multi-site Connect network, when a third party needs to use this function, it m ust share the same port num ber as the repeater.
`
`Edit - Conventional/XPT Trunking - General Setting - Network - Application Programming Interface - Radio GPS Slot2 Port
`
`Radio GPS Slot2 P o r t H ©
`
`To set the port number that the repeater uses for retransmitting GPS service. Tliis number m ust be unique.
`
`CX-1295.0207
`
`Moto-1053-05745666
`
`MOTOROLA EX. 2010
`IPR2017-02183
`Page 207 of 706
`
`
`
`Page 208 o f 706
`
`Edit
`
`Range
`
`10 2 4-65535
`
`Step
`
`efault
`
`1 D
`
`30004
`
`Note
`
`In an IP Multi-site Connect network, when a third party needs to use this function, it m ust share the same port num ber as the repeater.
`
`Edit - Conventioiial/XPT Trunkiiig - General Setting - Net^vork - Application Programming Interface - Radio Telemetry Slotl Port
`
`R a d io T e le m e tr y S lo tl P o r t H ©
`
`To set the port number that the repeater uses for telemetry service. This number m ust be unique.
`
`Range
`
`10 2 4-65535
`
`Step
`
`efault
`
`1 D
`
`30005
`
`Note
`
`In an IP Multi-site Connect network, when a third party needs to use this function, it must share the same port num ber as the repeater.
`
`Edit - Conventional/XPT Trunking - General Setting - Network - Application Programming Interface - Radio Telemetry Slot2 Port
`
`R a d io T e le m e tr y S lo tl P o r t H ©
`
`To set the port number that the repeater uses for telemetry service. This number must be unique.
`
`Range
`
`10 2 4-65535
`
`Step
`
`efault
`
`1 D
`
`30006
`
`Note
`
`In an IP Multi-site Connect network, when a third party needs to use this function, it m ust share the same port num ber as the repeater.
`
`Edit - Conventional/XPT Trunking - General Setting - Network - Application Programming Interface - Radio TMS Slotl Port
`
`R a d io T M S S lo tl P o r t H ©
`
`To set the port number that the repeater uses for retransmitting text message service. This number must be unique.
`
`CX-1295.0208
`
`Moto-1053-05745667
`
`MOTOROLA EX. 2010
`IPR2017-02183
`Page 208 of 706
`
`
`
`Page 209 o f 706
`
`Edit
`
`Range
`
`10 2 4-65535
`
`Step
`
`1 D
`
`efault
`
`30007
`
`Note
`
`In an IP Multi-site Connect network, when a third party needs to use this function, it m ust share the same port num ber as the repeater.
`
`Edit - Conventioiial/XPT Trunkiiig - General Setting - Net^vork - Application Programming Interface - Radio TMS Slot2 Port
`
`Radio TMS Slot2 P o r t H ©
`
`To set the port number that the repeater uses for retransmitting text message service. This number m ust be unique.
`
`Range
`
`10 2 4-65535
`
`Step
`
`1 D
`
`efault
`
`30008
`
`Note
`
`In an IP Multi-site Connect network, when a third party needs to use this function, it must share the same port num ber as the repeater.
`
`Edit - Conventional/XPT Trunking - General Setting - Network - Application Programming Interface - Radio Call Control Slotl Port
`
`Radio Call Control Slotl P o r t H ©
`
`To set the port number that the repeater uses for retransmitting call control service. This number must be unique.
`
`Range
`
`10 2 4-65535
`
`Step
`
`1 D
`
`efault
`
`30009
`
`Note
`
`In an IP Multi-site Connect network, when a third party needs to use this function, it m ust share the same port num ber as the repeater.
`
`Edit - Conventional/XPT Trunking - General Setting - Network - Application Programming Interface - Radio Call Control Slot2 Port
`
`Radio Call Control Slot2 P o r t ® ©
`
`To set the port number that the repeater uses for retransmitting call control service. This number m ust be unique.
`
`CX-1295.0209
`
`Moto-1053-05745668
`
`MOTOROLA EX. 2010
`IPR2017-02183
`Page 209 of 706
`
`
`
`Page 210 o f 706
`
`Edit
`
`Range
`
`10 2 4-65535
`
`Step
`
`efault
`
`1 D
`
`30010
`
`Note
`
`In an IP Multi-site Connect network, when a third party needs to use this function, it m ust share the same port num ber as the repeater.
`
`Edit - Conventioiial/XPT Trunkiiig - General Setting - Net^vork - Application Programming Interface - Radio Voice Service Slotl Port
`
`Radio Voice Service Slotl P o r tiH ©
`
`To set the port number that the repeater uses for retransmitting voice service. This number m ust be unique.
`
`Range
`
`1024 -C 65534
`
`Step
`
`efault
`
`2 D
`
`30012
`
`Note
`
`• In an IP Multi-site Connect network, when a third party needs to use this function, it must share the same port number as the repeater.
`• The parameter m ust be set even.
`
`ii
`
`Edit - Conventional/XPT Trunking - General Setting - Network - Application Programming Interface - Radio Voice Service SIot2 Port
`
`Radio Voice Service Slot2 P o r f H ©
`
`To set the port number that the repeater uses for retransmitting voice service. This number must be unique.
`
`Range
`
`1024 -C 65534
`
`Step
`
`efault
`
`2 D
`
`30014
`
`Note
`
`• In an IP Multi-site Connect network, when a third party needs to use this function, it m ust share the same port number as the repeater.
`• The parameter m ust be set even.
`
`Edit - Conventional/XPT Trunking - General Setting - Network - Application Programming Interface - Analog Call Control Port
`
`Analog Call Control Port H ©
`
`CX-1295.0210
`
`Moto-1053-05745669
`
`MOTOROLA EX. 2010
`IPR2017-02183
`Page 210 of 706
`
`
`
`Edit
`
`Page 211 o f 706
`
`The number of the port through which the repeater in Analog mode receives and transfers the call control services o f the third party. This number must be
`unique.
`
`Range
`
`10 2 4-65535
`
`Step
`
`efault
`
`1 D
`
`30015
`
`Note
`
`• This feature is available for repeaters in Analog mode only.
`• This parameter wiU be unavailable when Forward to PC is unchecked.
`
`Edit - Conventional/XPT Trunkiiig - General Setting - Networit - Application Programming Interface - Analog Voice Service Port
`
`Analog Voice Service Port
`
`This parameter is used to set the Analog Voice port number through which the repeater receives and transfers the voice service data o f the third party. This
`number m ust be unique.
`
`Range
`
`1 0 2 4 -6 5 5 3 4
`
`Step
`
`efault
`
`2 D
`
`30016
`
`Note
`
`• This feature is available for repeaters in Analog mode only.
`• This parameter must be an even number.
`• This parameter will be unavailable when Foi-ward to PC is unchecked.
`
`Edit - Conventional/XPT Trunking - General Setting - Network - Application Programming Interface - Self-Defined Message Slotl Port
`
`Self-Defined Message Slotl Port H ©
`
`This parameter is used to set the num ber o f the port that is used to receive and forward the customized message in Slotl.
`
`The customized message is the message data through custom protocol. Generally, the customized message means text message (including Quick Text^ and
`W ork O rders.
`
`Range
`
`1 0 2 4-65535
`
`Step
`
`efault
`
`1 D
`
`3017
`
`CX-1295.0211
`
`Moto-1053-05745670
`
`MOTOROLA EX. 2010
`IPR2017-02183
`Page 211 of 706
`
`
`
`Edit
`
`Note
`
`Page 212 o f 706
`
`This port number m ust be unique.
`
`Edit - Conventional/XPT Trunkilig - General Setting - Networli - Application Programming Interface - Self-Defined Message SIot2 Port
`
`Self-Defined Message Slot2 P ort^ H ©
`
`This parameter is used to set the num ber o f the port that is used to receive and forward the customized message in Slot2.
`
`The customized message is the message data through custom protocol. Generally, the customized message means text message (including Quick Text) and
`W ork O rders.
`
`Range
`
`1 0 2 4-65535
`
`Step
`
`efault
`
`1 D
`
`3018
`
`Note
`
`This port number m ust be unique.
`
`Edit - Conventional/XPT Trunldng - General Setting - Network - Application Programming Interface - GPS Port Identifier
`
`GPS Port Identifier
`
`This parameter is used to set the identifier of the GPS data that the repeater receives or transmits via its GPS Port. The identifier m ust be unique.
`
`To ensure that the repeater and the radio can decode the GPS data received from each other, you need to set the value of the GPS Port Identifier o f the
`repeater identical with that o f the Identifier of the radio's GPS Port.
`
`Range
`
`95 - 127
`
`Step
`
`efault
`
`1 D
`
`116
`
`Edit - Conventional/XPT Trunking - General Setting - Network - Application Programming Interface - RRS P ort Identifier
`
`RRS Port Identifier ■ ©
`
`This parameter is used to set the identifier of radio registration service (RRS) information that the repeater receives or transmits via the RRS Port. The
`identifier must be unique.
`
`To ensure that the repeater and the radio can decode the registration information received from each other, you need to set the RRS Port Identifier o f the
`repeater identical with the Identifier of the radio's RRS Port.
`
`Range
`
`95 - 127
`
`Step
`
`1
`
`CX-1295.0212
`
`Moto-1053-05745671
`
`MOTOROLA EX. 2010
`IPR2017-02183
`Page 212 of 706
`
`
`
`Edit
`
`Default
`
`115
`
`Page 213 o f 706
`
`Edit - Conventional/XPT Truiiking - General Setting - Networli - Application Programming Interface - Telemetry Port Identifier
`
`Telemetry Port Identifier
`
`This parameter is used to set the identifier of the telem etry data that the repeater receives or transmits via its Teleiiietn' Port . The identifier must be unique.
`
`To ensure that the repeater and the radio can decode the telemetry data received from each other, you need to set the value of the Telemetry Port Identifier
`o f the repeater identical with that o f the Identifier o f the radio's Telemetry Port.
`
`Range
`
`95 - 127
`
`Step
`
`efault
`
`1 D
`
`117
`
`Edit - Conventloiial/XPT Trunkuig - General Setting - Net^vork - Application Programming Interface - Self-Defined Message Port Identifier
`
`Self-Defined Message Port Identifier
`
`This parameter is used to set the identifier of the customized message that the repeater receives or transmits via the Self-Defined M essage S lotl Port or the
`Self-Defined M essage Slot2 Port. The identifier must be unique.
`
`To ensure that the repeater and the radio can decode the customized message received from each other, you need to set the value o f the Self-Defined
`Message Port Identifier of the repeater identical with that of the Identifier o f the radio's Self-Defined M essage Port.
`
`Range
`
`95 - 127
`
`Step
`
`efault
`
`1 D
`
`120
`
`Edit - Conventional/XPT Trunking - General Setting - Network - Application Programming Interface - RCP Port Identifier
`
`RCP Port Identifier
`
`This parameter is used to set the identifier of the call control data that the repeater receives or transmits via its RCP Port . The identifier must be unique.
`
`To ensure tha